SOLAR PANEL SIZE |
|
|
|
|
|
|
|
|
NORTHWEST POWER CO |
|
|
|
www.nwpwr.com |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Total average amp hours per day from
the Systems Loads
Sheet line 10 |
________ |
________ |
|
|
|
|
|
|
|
|
|
|
2. Multiply line 1 by 1.2 to compensate for loss from
battery charge/discharge |
___1.2_____ |
________ |
|
|
|
|
|
|
|
|
|
|
3. Average sun hours per day in your area |
|
|
|
__________ |
________ |
|
|
|
|
|
|
|
|
|
|
4. Divide line 2 by line 3. This is the total solar array
amps required. |
__________ |
________ |
|
|
|
|
|
|
|
|
|
|
5. Optimum or peak amps of solar module used. See module
specifications example is (SP75
is 4.4 amps ) |
__________ |
________ |
|
|
|
|
|
|
|
|
|
|
6. Total number of solar modules in parallel required.
Divide line 4 by 5 |
__________ |
________ |
|
|
|
|
|
|
|
|
|
|
7. Round off to the next highest whole number. |
|
|
__________ |
________ |
|
|
|
|
|
|
|
|
|
|
8. Number of modules in each series string to provide DC
battery voltage: |
__________ |
________ |
|
|
|
|
|
|
|
|
|
|
9. Total number of modules required: Multiply line 7 by
line 8 |
|
__________ |
________ |