MX Series
Home Exeltech Outback Inverters

 

Home
Up

EXELTECH manufactures the world's first truly redundant, modular inverter system; the most reliable inverter system available. No single malfunction will cause the inverter system to fail. Modules are "hot" insertable ( except for 12vdc). Power levels are expandable, and modules can be added or replaced without interruption in power to your critical loads.

The Exeltech MX series inverters are true sine wave, very versatile, custom inverters designed for use where reliability and high power quality is extremely important. MX systems can be configured with power levels from 1000 watts to 20kW at 120Vac output, to 40kW at 240Vac bi-phase, or to 60kW at 208Vac 3 phase.

Power levels are expandable, and inverter modules can be upgraded or replaced, and if designed as a redundant system, a replacement can occur while the system is on line without interruption in power to your loads.

The output voltage is precisely regulated, so that no measurable voltage change occurs on the output when the input voltage changes over its wide voltage range. Less than 0.5 volt change in output will occur when the output load varies from 0 to 100% of rated power. With distortion of 2% maximum, this offers the cleanest sine wave power available.

The system is extremely compact and lightweight. Modules, cards and cages are combined to create the inverter needed.

A Master Module combines the control signals of a Control Card with a Power Module. This is a space saving solution when redundancy is not necessary. The Master Module provides control signals to up to 19 power modules.

The Power Module is a 1000 watt slave power inverter. It requires drive signals from a Master Module or a Control Card. This module is the backbone of the inverter system and will be the majority of the modules in most systems.

The Control Card provides all the control functions fro the Power Modules. Adding a second Control Card provides redundant operation as only one Control Card is required to operate the system.

The Alarm Card is necessary in a redundant system. It allows the inverter to detect a Control Card failure and switch to the backup Control Card. The Alarm card provides LED indicators for DC on, inverter on, load presence, inverter fail, breaker open, high temperature, and low voltage and "form-C" contact closures for minor failure, major failure, inverter failure, bypass, DC failure and AC failure.

The Transfer Switch allows the inverter to automatically switch between inverter power and a secondary source of AC power. The transfer has a maximum capacity of 50 amps and a typical transfer time of 4ms.

Determine the components to order below. For 120/240v operation, order twice as many Master Modules or Control Cards and Cages. For 3-Phase order 3 times as many Master Modules or Control Cards and Cages.

Requirement

MX Component

Description

Price

Choose One

Master Module

(12vdc)

contact us for other voltages

Use 1 per system if you are not building a redundant system  
$944.00  & free shipping in the 48 States

Control Card

(12vdc)

contact us for other voltages

Use 2 in each system for redundant operation  
$400.00  & free shipping in the 48 States

Choose as many as necessary

Power Module

(12vdc)

Use one for each 1000 watts output if using Control Cards or 1 less than the total output required if using a Master Module. Add 1 additional for n+1 redundancy.  
$899.00  & free shipping in the 48 States

Choose One

Rack A 19"

(cage)

1 required - holds Transfer Switch/Alarm Module and 2 Control Cards with up to 4 Power Modules or 1 Master Module with up to 4 Power Modules
$540.00  & free shipping in the 48 States

Rack A 23"

(cage)

1 required - holds Transfer Switch/Alarm Module and 2 Control Cards with up to 5 Power Modules or 1 Master Module with up to 5 Power Modules
$540.00  & free shipping in the 48 States

Choose One

Rack B 19"

(Exp Cage)

Holds up to 5 Power Modules - for expansion only. Width must match Rack A Choice
$540.00  & free shipping in the 48 States

Rack B 23"

(Exp Cage)

Holds up to 6 Power Modules - for expansion only. Width must match Rack A Choice
$540.00  & free shipping in the 48 States

Optional

Transfer Switch

(up to 5kW)

Optional on Redundant and Non-redundant systems
$948.00  & free shipping in the 48 States

Alarm Card

1 required for redundant systems
$277.00  & free shipping in the 48 States

Email us separately after your order is placed to let us know the input voltage and output voltage you require. Standard voltages for input are 12, 24, or 48 vdc. Also available in 32, 66, and 108vdc.  Please include a Phone number so we may contact you.

or call 970-785-2707

Allow 6-7 weeks for assembly, testing and delivery.

 

NORTHWEST POWER CO, LLC
Mailing to: P.O. Box 271 Platteville, CO 80651   Location: 303 Elizabeth Ave Platteville, CO 80651
Phone # 970-785-2707       FAX: # 970-785-2713

Email at: info@nwpwr.com